4. Secure and tighten the mounting screws.
CAUTION: MAKE SURE THE HOOD IS
SECURE BEFORE RELEASING.
Ductwork Installation
5. Using Reference E from Table 1 and
measurements on Page 12, mark the
leveling point for duct cover-mounting
bracket.
6. Secure the duct cover-mounting bracket to
the wall with two screws (not provided).
(Figure 5 and Figure 8) Make sure all
screws are tightened. NOTE: Inner duct
cover will cover the duct cover-mounting
bracket.
7. Use 6” steel pipe (not provided) to connect
the plastic exhaust on the hood to the
ductwork above. Use duct tape to ensure
all joints are secure and air tight as shown
in Figure 6.
Wiring to Power Supply
SAFETY WARNING
RISK OF ELECTRICAL SHOCK. THIS
RANGE HOOD MUST BE PROPERLY
GROUNDED. MAKE SURE THIS IS DONE
BY A SPECIALIZED ELECTRICIAN IN
ACCORDANCE WITH ALL APPLICABLE
NATIONAL AND LOCAL ELECTRICAL
CODES. BEFORE CONNECTING WIRES,
SWITCH POWER OFF AT SERVICE PANEL
AND LOCK SERVICE PANEL TO PREVENT
POWER FROM BEING SWITCHED ON
ACCIDENTALLY.
8. Connect three wires (black, white and
green) to house wires and cap with wire
connectors. Connect according to color:
black to black, white to white, and green to
green as shown in Figure 7.
9. Test the operation of the hood before
performing the next step. Make sure power
is supplied to the hood.
Duct Cover Installation
10. Slide inner duct cover up 2 inches before
sliding entire duct cover onto the hood.
(Figure 8)
11. Align the inner duct cover to the duct cover-
mounting bracket. Secure inner duct cover
with two (4x8 mm) screws (provided).
Figure 5
Figure 6
Figure 7
Figure 8